Features

Three-pass design

Technical features from the catalogue and user manual.

  • The design lets the user control the heat level with ease.
  • The three-pass design lengthens the flue gas path, lowers flue gas temperature and saves fuel.
  • Every boiler is tested at 1.5 times its operating pressure.
  • Heat transfer is spread evenly across all surfaces, which extends boiler life.
  • It can burn natural gas, fuel oil, diesel and LPG.
  • An optional cylinder or heat exchanger can be added to produce domestic hot water.
Models

YT-3G models

Model code: series + capacity, for example YT-3G-400. The circulation pump and burner are not included.

YT-3G

Single phase

Models 150 – 250 come with a single-phase electrical panel.

YT-3G

Three phase

Models 300 – 800 come with a three-phase electrical panel.

Technical data

Dimensions and technical table

The table scrolls horizontally; the values match the catalogue. Technical data may change as products are developed.

Dimensions
ModelUnitYT-3G-150YT-3G-200YT-3G-250YT-3G-300YT-3G-350YT-3G-400YT-3G-500YT-3G-600YT-3G-700YT-3G-800
Width (A)mm1135113511351135113511351185118512351235
Depth (L)mm1710181020202070217022702320242029652895
Boiler height (H)mm1515151516901690169016901790189023052305
Flue diameterØ mm190190300300350350400400450450
Boiler flow / returnØ inch2333555556
Expansion tank flow / returnØ inch111 ¼1 ¼1 ¼1 ¼1 ¼1 ¼1½1½
Fill – drainØ inch3/43/43/43/43/43/43/43/43/43/4
Technical data
ModelUnitYT-3G-150YT-3G-200YT-3G-250YT-3G-300YT-3G-350YT-3G-400YT-3G-500YT-3G-600YT-3G-700YT-3G-800
Fuel typeNatural gas – dieselNatural gas – dieselNatural gas – dieselNatural gas – dieselNatural gas – dieselNatural gas – dieselNatural gas – dieselNatural gas – dieselNatural gas – dieselNatural gas – diesel
Heating capacitykW174223291349407466582698814931
Heating capacitykcal/h150,000200,000250,000300,000350,000400,000500,000600,000700,000800,000
Combustion chamber height (Ø)mm450480480550550550550550700750
Combustion chamber depth (L)mm1200120012001400140014001500160017001800
Combustion chamber volumedm³190217217253332332353380653794
Combustion chamber pressurembar0.90.91.11.11.11.11.91.91.91.9
Water volumelt950101011001250132014501600171018501950
Boiler weightkg8509109801,0901,2001,3001,5151,9152,3152,715
Required flue draughtmbar0,44–0,470,44–0,470,44–0,470,46–0,490,46–0,490,46–0,490,51–0,540,51–0,540,53–0,570,53–0,57
Temperature control range°C35–8535–8535–8535–8535–8535–8535–8535–8535–8535–85
Maximum operating pressurebar3333333333
Test pressurebar4.54.54.54.54.54.54.54.54.54.5

A = width, L = depth, H = boiler height. The circulation pump and burner are not included.

Installation and commissioning Once the system has been filled with water, commissioning is carried out by our authorised service. Before installation see the installation notes page.
Product enquiry form

Request a quotation for YT-3G

Tell us the area to be heated, its insulation and your preferred fuel; we will calculate the capacity and send you a suitable model and quotation the same day.

Please enter your first name and surname.
Please enter a valid e-mail address.
The telephone number must have at least 10 digits.
Please enter your city.
You need to give consent to continue.
WhatsApp